Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/20/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
Nailing at ledger to girder trusses not per schedule. Provide blocking for floor truss behind stringers. Provide 24” o.c ladder blocking at t1 per sd3/g. Missing a35 per detail sd2/11. Nailing at belly band not per schedule. Provide fix on damaged gusset plates. Damaged floor truss. Missing shot pins. Treads are all backwards. Stopped inspection. Other items may vary. 7/20/2026 |
| 07/27/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
Partial pass. Provide nails at marked areas 2nd floors. Loose shear walls marked areas. 7/27/2026 |
| 08/05/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
8-5-26 corrections made exterior interior clip, sheathing framing approved |