Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0925-00588

Parcel: 141460940


Addresses:

9568 E FRIEDEL DR

Inspection Status: Not Ready

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
07/20/2026 COT - RSBU - Roof Nailing  Not Ready Nailing at ledger to girder trusses not per schedule. Provide blocking for floor truss behind stringers. Provide 24” o.c ladder blocking at t1 per sd3/g. Missing a35 per detail sd2/11. Nailing at belly band not per schedule. Provide fix on damaged gusset plates. Damaged floor truss. Missing shot pins. Treads are all backwards. Stopped inspection. Other items may vary. 7/20/2026