Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/10/2026 | COT - RSBU - Roof NailingĀ | Re-inspection required | 07/10/2026 Add anchor bolts as marked. Add jack stud on both sides of rear partio header, plan calls for three. Rear patio missing h2.5 clips or 6" structural screws, loose panels on roof as marked. Engineer fix for damaged roof truss. |
|
| 07/16/2026 | COT - RSBU - Roof NailingĀ | Partial Pass | 07/16/2026 Corrections made. Partial pending engineer fix to roof truss. Verify at intermediates. |