Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0925-00584

Parcel: 141461220


Addresses:

9511 E FRIEDEL DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
09/28/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 9/28/26: add 3 nails 6" o.c. At sole plate to decking & nail flush, add nails to sheathing where nails over penetrate more than 1/16", add staples to garage t-ply at marked areas, add nails to Southwest SW upstairs, missing truss bracing upstairs, add shot pins to marked areas-water heater framing, add nails to loose roof panels at marked locations.