Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0925-00538

Parcel: 140443500


Addresses:

7639 S BEST MATE PL

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready 10.27.2025
Not ready.
10/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10.28.2025
HTT4 for HD1 detail at front of garage not set, missing shear wall near front porch, add staples to staples within 3/8” buffer of edge to north shear wall as marked, missing 2x8 ledger at front of garage per detail SD4-37, double girder needs continuous stud connection at belly band, add web stiffener to garage entry per detail and filler at the hangers, add nails to floor joists to top plate per connection schedule throughout.
10/29/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10.29.2025
Corrections made to prior inspection.