Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Sw11 and greater require anchor bolts with plates as per plans Over penetration at ply shear, examples marked RSP4 issues at north side BE ADVISED: INSPECTION STOPPED, MORE ITEMS MAY BE ADDED. |
|
| 06/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | ||
| 06/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required (with fee) | 6.8.26 Anchor bolt configuration and spacing still does not meet specifications per plans at detail for sw11. |