Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 08/19/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
8-19-26 add shot pins to marked location throughout refer to general structure notes K .5* add anchor bolt to Marked locations around perimeter throughout* RSP4 missing at east wall exterior* trimmer stud nail to King stud shall be 8 inches on center at all window framing areas throughout refer to detail sn4 13.a* stopped inspection at this time* roof nailing at garage is not complete in certain areas please double check roof nailing at garage. reinspection is required |
| 08/20/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
8-20-26 all corrections have been made OK to continue |