Permit: TC-MDP-0925-00503

Parcel: 141156900

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Gas Pressure Test 

Date Description Inspector Results Comments
09/14/2026 COT - RSPL - Gas Pressure Test  Re-inspection required 9/14/26: Electrical Clearance not ready (Riser not in place,Breaker must be 20 Amp),lath incomplete (all penetrations shall be caulked, Finish installation), electrical wiring shall not be closer than 1 1/4" from face of stud, seal all penetrations through vapor barrier (including attic space), seal penetrations through top plate throughout, seal conduit to island, smoke alarm must be 3' from bathroom and vents, secure thermostat wire, support flex duct 4' o.c, duct torn at master bath and living room and entry hallway, gusset plate at kitchen improperly installed. STOPPED INSPECTION MORE ITEMS MAY BE ADDED (plumbing was not walked)
09/16/2026 COT - RSPL - Gas Pressure Test  Passed 9-16-26 gas pressure test approved