Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 08/26/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
8-26-26 all windows, trimmer to king stud require, (2)16 D nails, 8 inches on center on each side* all top plates splices are required (12)16d nails on each side per planes SN3 7A* shot pins are required throughout on non-bearing walls 24 inches on center per notes SN2 K5* stopped inspection at this time. More items may be noted. |
| 08/28/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |