| 06/06/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
6-6-25: replace/add nails to or on 2-RSP4's located on west side, add anchor bolt to marked area next to back door and at shear walls, missing HTT55-KT/HTT45KT at garage, add shot pins at marked locations, add 1" staples 3" o.c. To green T-ply bedroom behind garage, add nails at edge/joints at and above garage to sheathing-several nails were marked because of over penetration and missing nailing along edge above garage opening.Loose roof panel midway point of garage. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED. |
| 06/10/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
6-10-25: exterior clips/sheathing approved. |