Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
06/06/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-6-25: replace/add nails to or on 2-RSP4's located on west side, add anchor bolt to marked area next to back door and at shear walls, missing HTT55-KT/HTT45KT at garage, add shot pins at marked locations, add 1" staples 3" o.c. To green T-ply bedroom behind garage, add nails at edge/joints at and above garage to sheathing-several nails were marked because of over penetration and missing nailing along edge above garage opening.Loose roof panel midway point of garage. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED.
06/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6-10-25: exterior clips/sheathing approved.