Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 136480290


Addresses:

9822 E GRAY HAWK DR


Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Backwater Valve 

Permit Number - TC-MDP-0924-01128

Inspection Description - COT - RSPL - Backwater Valve 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/16/2025 COT - RSPL - Backwater Valve  Re-inspection required 1-16-25, not ready.
01/17/2025 COT - RSPL - Backwater Valve  Passed 1/17/25: underground plumbing is complete and connected to main sewer line, entire system is under a water test with no leaks, green tracer wire is installed from clean outs to sewer connection, and backwater valve is installed between clean outs. Okay to shade pipes and backfill trenches.