Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0924-01124
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/07/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 12/31/24 LUS24's needed at 2x6 on covered back patio. Anchor bolts must be secured, have framer walk through and check. 01/07/25 1. All SW11 or greater shear wall require anchor bolts with .0229"x3"x3" plate washer. 2. Patio not built per plan; the east beam should be a 6"x8" and pocket into wall; plans also call for BC6 post caps SE and SW posts. |
|
01/10/2025 | COT - RSBU - Roof Nailing | Passed | passed. | |
12/31/2024 | COT - RSBU - Roof Nailing | Partial Pass | 12/31/24 LUS24's needed at 2x6 on covered back patio. Anchor bolts must be secured, have framer walk through and check. |