Permit: TC-MDP-0924-01104

Parcel: 141460750


Addresses:

9543 E HARKES DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
05/19/2025 COT - RSBU - Roof Nailing  Re-inspection required 5/19/25
1. Garage truss not per elevation "O" plan calls for M10-M11 truss.
2. Missing HU410 Hgrs at Flr truss F11 in garage, see pg. S2.1
3. F14 floor is not per plan, the one closest to stairs when you walk in from garage.
4. Flr truss F09 not per plan.
*****STOPPED INSPECTION MORE ITEMS MAYBE ADDED*****
05/29/2025 COT - RSBU - Roof Nailing  Partial Pass 5-29-25: contractor obtained new truss calculations/fix on what was previously mentioned from inspection dated, 5-19-25. Contractor to submit new truss calculations to the city for review/approval. Okay to continue construction at own risk.
07/02/2025 COT - RSBU - Roof Nailing  Passed 7/2/25 passed