| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/19/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Fully nail Simpson clips at garage, roof of garage, and 2nd floor roof. Nails on 2nd floor sil plates to floor, anchor bolts at marked locations. STOPPED INSPECTION MORE ITEMS MAY BE ADDED | |
| 04/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 4-9-25, add 2 anchor bolts on each side shear walls of garage exterior plate (2 anchor bolts are required for any plate 12" or more on exterior walls). Also, properly nail down all nails not flush to sill plate/ floor decking on west side on 2nd floor. | |
| 04/14/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/14/25 pass |