9561 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0924-01103

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/19/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Fully nail Simpson clips at garage, roof of garage, and 2nd floor roof. Nails on 2nd floor sil plates to floor, anchor bolts at marked locations. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
04/09/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4-9-25, add 2 anchor bolts on each side shear walls of garage exterior plate (2 anchor bolts are required for any plate 12" or more on exterior walls). Also, properly nail down all nails not flush to sill plate/ floor decking on west side on 2nd floor.
04/14/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/14/25