Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
|
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
6-16-25: block 4-gang box at kitchen, tape tear on at flex at family room, missing mud ring, instal FHA plate for kitchen exhaust, firefoam penetrations at decking on bedroom 2, firefoam orange whip exiting out from bedroom 2 closet, add receptacle or adjust to max spacing of 12' in bedroom 2, firefoam flex chute at upstairs, firefoam eastside deck penetration at loft, add nails to sill to decking at marked locations, completely seal/fireafoam penetrations at garage and throughout. |
| 06/18/2025 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
Approved. All corrections were made. 6/18/2025 |