01/07/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Must fully foam and seal vapor barrier at window near island, fire foam white low voltage wire penetration at hallway by island and garage, add insulation or move Pex at shower 12" from recessed light, same in laundry room.
01/13/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 1/13/25 corrections made