Inspection Status: Partial Pass

Inspection History: COT - RSEL - Grounding/BondingĀ 

Date Description Inspector Results Comments
02/07/2025 COT - RSEL - Grounding/BondingĀ  Partial Pass Concrete forms are set in place, masa clips, A8,A11, and A14 Simpson shear wall ties are nailed to the form per plan requirements. Post tension cabling is evenly spaced and supported up off of ground. Ufer ground is installed on right side of garage. Underground electrical is installed for kitchen island. Underground plumbing is properly wrapped with foam. Okay to pour concrete for footings and slab.
03/12/2025 COT - RSEL - Grounding/BondingĀ  Passed