Inspection History Details
Inspection Status: Not Ready
Inspection History: ENGR Engineering Final
Permit Number - TC-MDP-0924-01039
Inspection Description - ENGR Engineering Final
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2025 | ENGR Engineering Final | Not Ready | Final grade does not facilitate drainage from backyard. There is an increase in elevation from the Northeast corner of the house to the A/C unit and another increase in elevation from the North gate to the Northwest corner of the screen wall. The drainage pipe laid next to the A/C unit has been buried on the outlet side which will result in standing water in the pipe. | |
| 04/18/2025 | ENGR Engineering Final | Not Ready | Grade on North side of house has two elevation increases. From the NE corner of the house to the East side of the A/C unit there is a 3" increase. From the North gate to the end of the screen wall there is a 1.5" increase. Photos included to show difference, measured from level line below stucco. Same results were found when measured from grout lines on wall. This side of the house handles the water shed from the entire rear of the lot. Grade needs to be a continuous drop from back to street. | |
| 04/22/2025 | ENGR Engineering Final | Passed |