Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0924-01019
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 11-19-24, add anchor bolts to marked areas, A-35'S not fully fastened to top plates on east and west walls (in many places framers are using 1 nail). H-25'S must be nailed to interior load bearing framing at intermediate inspection. | |
| 11/22/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 11-22-24, anchor bolts are required within 12" of beginning of an edge. On the southeast corner of exterior wall near back patio there are 3 masa clips in a row with 1 leg up and a shot pin in between. An anchor bolt is required as a shot pin does not suffice. Also, I observed a few A-35's on the Southwest bedroom where the nails were added but not fastened all the way down to top plates. Have framers walk it in its entirety and properly nail down clips to areas in question. | |
| 12/13/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 12/13/24 corrections have been made. Ok to proceed. |