Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0924-01009
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 18 March 25 1. Broken Truss web T19, Web 7. Provide engineer letter with repair. 2. Shear wall anchors need to 32" on center. 3. Provide Truss plan for T19, it is missing in the truss Calcs binder. |
||
| 03/18/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 18 March 25 1. Broken Truss web T19, Web 7. Provide engineer letter with repair. 2. Shear wall anchors need to 32" on center. 3. Provide Truss plan for T19, it is missing in the truss Calcs binder. 4. Interior Load bearing wall needs to have anchor bolts every 6ft. |
|
| 03/19/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | Partial pass pending engineering fix on truss t19, check at intermediate stage | |
| 04/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 3 April 25 pass |