Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0923-01588

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/24/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing anchor bolt right side of house, missing studs left side of garage for GTs at second floor, add blocking between floors to allow continuous load transfer from second to first floor at all bearing posts.
05/29/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed