Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0923-01519
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/2024 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | 3/22/24: ufer needs to be moved to northwest corner, holdowns at northwest corner not fastened to reinforcement, stationary end of PT can only expose 1" of cable | |
03/25/2024 | COT - RSBU - Excavation/Rebar/Zoning | Not Ready | 3/25/24: not ready still needs corrections made | |
03/26/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed |