Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 131060820


Addresses:

1845 S POETRY LN


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0923-01519

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/22/2024 COT - RSBU - Preslab   Re-inspection required 3/22/24: ufer needs to be moved to northwest corner, holdowns at northwest corner not fastened to reinforcement, stationary end of PT can only expose 1" of cable
03/25/2024 COT - RSBU - Preslab   Not Ready 3/25/24: not ready still needs corrections made
03/26/2024 COT - RSBU - Preslab   Passed