Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2024 | BULD - Electrical Clearance | Re-inspection required | Electrical underground at O.E. sticking out of wall, middle stairwell landing missing outlet, leak at dining coming down from second floor master shower, master shower missing cleanout, smoke alarms must be 3’ away from bathroom containing bathtub or shower, water heater flu pipe missing nail plate at sole plate in bedroom 2, working platform in attic for air handler must be a minimum 30” in depth and width per M1.1 plans and code. | |
03/21/2024 | BULD - Electrical Clearance | Passed |