Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0923-01496
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/13/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Front STHD Holddown over spalled left side of house, missing 5th stud right side of garage for beam support, completely install LUS48 hanger, fully nail HTT hold down, anchor bolts missing at back garage shear wall, missing rsp4 clips at back porch, add anchor bolt left side of house, missing h2.5 clip left side of house, over spanned studs at room front of house, pop out must have vertical blocking. | |
02/16/2024 | COT - RSBU - Exterior Clips/Sheathing | Canceled | Cancelled per Austin. | |
02/20/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |