Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0923-01496

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
02/13/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Front STHD Holddown over spalled left side of house, missing 5th stud right side of garage for beam support, completely install LUS48 hanger, fully nail HTT hold down, anchor bolts missing at back garage shear wall, missing rsp4 clips at back porch, add anchor bolt left side of house, missing h2.5 clip left side of house, over spanned studs at room front of house, pop out must have vertical blocking.
02/16/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Cancelled per Austin.
02/20/2024 COT - RSBU - Exterior Clips/Sheathing  Passed