Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0923-01475
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2024 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | 4/2/24: no plans. Missing post tension. Masa clips missing. | |
| 04/05/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 4/5/24: Plans are onsite, all post tension cabling is installed, Masa clips have been added were missing. Rebar for Ufer ground is installed in footing on east side of house. Underground electrical for living room outlet and kitchen island are installed. Okay to proceed with concrete pour. |