Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0923-01475
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/26/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | All masa clips are properly secured to bottom plate, all trusses are properly secured to top plate with H2.5 clips, bottom plates are secured to concrete floor with shot pins or bolts. All exterior sheathing for shear walls are properly secured to studs per nailing pattern on plans. Okay to proceed with window installation. |