Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Canceled | Canceled per contractor. 7/29/2026 | |
| 08/03/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 08/03/2026 Add sheathing to entrance at piers and steel washer plates to anchor bolts. Add strap at beam to post at rear patio. Provide truss calcs. |
|
| 08/05/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required (with fee) | 8-5-26: per SN1 Note G-All anchor bolts shall be installed with 3X3" washers, garage shear walls must be nailed at 4" o.c. along edges/joints 12" o.c. In the field, add nails to loose roof panel at entryway-see marked location. | |
| 08/06/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 8-6-26: exterior clips/sheathing/framing approved. |