Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/23/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 04/23/2026
Rear SW11 is over-penetrated throughout - add nails and ensure nails are flush to OSB. Add anchor bolts as marked between Masa clips with arms up. Add (6) H2.5 clips for A3 trusses to top plate at 3rd bearing point.
04/24/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required (with fee) 04/24/2026
No corrections made to listed items on 4/23/2026. Reschedule when ready, re-inspection fee required.