Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0825-00461

Parcel: 14101013E


Addresses:

10010 E LEBARON

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/09/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 04/09/2026
Add h2.5 clips to A3-A4 trusses requiring 3rd bearing to top plate, add hangers to 2x6 rafters at ledger in rear covered patio, add nails to SW11 where over-penetration occurs and add washer plates to SW11 where missing near entryway and interior shear wall, add anchor bolts at marked locations, add shot pins at marked locations, provide printed truss layout showing D2 trusses in rear bedroom.
04/10/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 04/10/2026
All corrections made to prior inspection, ok to proceed.