Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/09/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 04/09/2026 Add h2.5 clips to A3-A4 trusses requiring 3rd bearing to top plate, add hangers to 2x6 rafters at ledger in rear covered patio, add nails to SW11 where over-penetration occurs and add washer plates to SW11 where missing near entryway and interior shear wall, add anchor bolts at marked locations, add shot pins at marked locations, provide printed truss layout showing D2 trusses in rear bedroom. |
|
| 04/10/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 04/10/2026 All corrections made to prior inspection, ok to proceed. |