Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0824-00981
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 12-6-24, missing lus26 hangers at porch, shear walls#9 calls for 2 inches on center, missing nails to several A-35's throughout second floor, nail down all truss bracing on second floor.STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED. | |
12/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 12/12/24 corrections made |