Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0824-00910
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 5/13/25 1.Truss above hood will need repair and engineer letter. 2. I counted 19 circuits, panel schedule calls for 27. Jim with Austin electric spoke with Juan Garcia and this is approved. |
|
| 05/13/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | According to the plans, we are shorts branch circuits. Lower t stat. Missing receptacle right side of SGD. bearing truss above kitchen hood has been damaged. 5/9/2025 5/13/25 1.Truss above hood will need repair and engineer letter. 2. I counted 19 circuits, panel schedule calls for 27. Jim with Austin electric spoke with Juan Garcia and this is approved. |
|
| 05/19/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Canceled | ||
| 05/20/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 5/20/25 partial pass, fix in place for truss waiting on engineering letter | |
| 05/28/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 5-28-25, intermediates approved. Engineer fix to be submitted to the city for review. |