Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Roof Nailing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Roof Nailing | Partial Pass | 7/7/25 Partial pass, ok to dry roof. Will need Engineer letter with fix recommendations at the following cracked/broken Truss: 1. Truss number 15, broken Top Chord and web 2. Truss number 9, broken top chord 3. Truss number 8, Web splitting. |
||
| 07/08/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 7/8/25 No repairs made. |
|
| 07/09/2025 | COT - RSBU - Roof Nailing | Passed | 7/9/25 repairs made |