Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0824-00862
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2025 | RSBU - Building Final | Re-inspection required | 7/8/25: Address missing at SFR, exterior plastic piping must be coated for UV Protection, hose bib must be insulated and wrapped for UV protection, condensate drains must be properly terminated with 90 degree fitting, water hammer arrestor required at dishwasher, GFCI at kitchen counter not properly functioning, INCLUSIVE HOME DESIGN NOTEs 1. PROVIDE AT LEAST ONE EXTERIOR ACCESSIBLE ROUTE AND ENTRANCE. ROUTE MAY ORIGINATE FROM CARPORT, DRIVEWAY, PUBLIC STREET, OR SIDEWALK. SLOPE OF THIS ROUTE SHALL NOT EXCEED ONE FOOT RISE PER TWENTY FEET HORIZONTAL DISTANCE (1:20), UNLESS A RAMP PER IRC IS CONSTRUCTED. NOTE: INDICATE THE "EXTERIOR ACCESSIBLE ROUTE" AND "ACCESSIBLE ENTRANCE" (ACC ENT) ON SITE PLAN. 2. ACCESSIBLE ENTRANCE: PROVIDE MINIMUM ONE NO-STEP LEVEL ENTRANCE THAT IS A MINIMUM 32 INCHES WIDE AND MEETS THE DOOR HARDWARE REQUIREMENTS PER THIS ORDINANCE. (NOT: EXIT DOORS ARE REQUIRED TO BE 36 INCHES MINIMUM AND THE GARAGE SHALL NOT BE USED AS AN EXIT). |
|
| 08/06/2025 | RSBU - Building Final | Passed | 8.6.25 Acceptable corrections made as requested Approved Inspectors note: approved bathroom plan in smaller unit is hazardous and in my opinion counter compliant to the code. |