Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 124080910

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Permit Number - TC-MDP-0824-00862

Inspection Description - RSBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/08/2025 RSBU - Building Final  Re-inspection required 7/8/25: Address missing at SFR, exterior plastic piping must be coated for UV Protection, hose bib must be insulated and wrapped for UV protection, condensate drains must be properly terminated with 90 degree fitting, water hammer arrestor required at dishwasher, GFCI at kitchen counter not properly functioning, INCLUSIVE HOME DESIGN NOTEs
1. PROVIDE AT LEAST ONE EXTERIOR ACCESSIBLE ROUTE AND ENTRANCE. ROUTE MAY ORIGINATE FROM CARPORT, DRIVEWAY, PUBLIC STREET, OR SIDEWALK. SLOPE OF THIS ROUTE SHALL NOT EXCEED ONE FOOT RISE PER TWENTY FEET HORIZONTAL DISTANCE (1:20), UNLESS A RAMP PER IRC IS CONSTRUCTED. NOTE: INDICATE THE "EXTERIOR ACCESSIBLE ROUTE" AND "ACCESSIBLE ENTRANCE" (ACC ENT) ON SITE PLAN. 2. ACCESSIBLE ENTRANCE: PROVIDE MINIMUM ONE NO-STEP LEVEL ENTRANCE THAT IS A MINIMUM 32 INCHES WIDE AND MEETS THE DOOR HARDWARE REQUIREMENTS PER THIS ORDINANCE. (NOT: EXIT DOORS ARE REQUIRED TO BE 36 INCHES MINIMUM AND THE GARAGE
SHALL NOT BE USED AS AN EXIT).
08/06/2025 RSBU - Building Final  Passed 8.6.25
Acceptable corrections made as requested
Approved

Inspectors note: approved bathroom plan in smaller unit is hazardous and in my opinion counter compliant to the code.