Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0823-01447
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/27/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 3/27/24: Anchor bolts missing 12" from edge of sill plate throughout , 4 continuous M.A.S.A clips with one leg up on south east corner of house, sill plates longer than 12" require 2 Anchor bolts (missing at north east corner), shot pins required at 3' o.c at interior walls missing throughout, missing shot pins at sill plate edges, shear wall 7 nailing not per schedule, | |
03/28/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections were made. 3/28/2024 |