Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0823-01447

Parcel: 103192940


Addresses:

2388 W OWL PERCH LP

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
06/17/2024 COT - RSPL - Plumbing Final  Re-inspection required 6/17/24: cut clean-outs to grade, T&P must terminate 6" above grade, properly seal penetration through stucco around T&P drain, weep screed damaged, electrical Whip at HVAC must be properly supported and properly attached to 90 degree fitting, properly insulate refrigerant lines, HVAC must have a 3" clearance from grade, MULTIPLE CIRCUITS TIED IN TOGETHER, panel cover must be replaced, Gas meter not installed, Panel schedule must be visible, range and dishwasher not installed. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
06/24/2024 COT - RSPL - Plumbing Final  Passed