Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0823-01422
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/13/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 9/13/24: ALL LISTED ITEMS WERE FOUND ON FIRST FLOOR EAST UNIT. STOPPED INSPECTION. Anchor bolt spacing at Shearwalls not per plan, anchor bolts must be properly fastened, holdowns must be properly fastened, Anchor bolts required 12" from edge of sill plate, Web stiffeners must be properly fastened, missing web stiffeners throughout,post to beam connections not per plan, SW1 schedule fasteners not per schedule, Missing jack/king studs at openings. field modified TJI must be repaired/replaced. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
09/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |