Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 11/16/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Missing anchor bolts at shear walls, shear wall at front of house not per nailing schedule, replace stud for column at front porch, column to girder requires cs16 strap at second floor, over spanned wall at back room second floor. |
| 12/14/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|