Parcel: 141450650

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0823-01388

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/16/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing anchor bolts at shear walls, shear wall at front of house not per nailing schedule, replace stud for column at front porch, column to girder requires cs16 strap at second floor, over spanned wall at back room second floor.
12/14/2023 COT - RSBU - Exterior Clips/Sheathing  Passed