08/20/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required DWV not on test. Secure and add nail plate to condensation line. Fire foam condenser lines. Staples going through vent pipe powder room. Add supports for vent line at 90* above garage door. Secure exhaust fan. Stopped inspection. 8/20/2024
08/23/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required DWV not on test. Secure and add nail plate to condensation line. Fire foam condenser lines. Staples going through vent pipe powder room. Add supports for vent line at 90* above garage door. Secure exhaust fan. Stopped inspection. 8/20/2024
8/23/24: leak at clean out at laundry and 90 degree above top plate, seal all penetrations through vapor barrier, properly support condensate drain .
08/26/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 8/26/2024 corrections were made.