Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0823-01379
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Partial Pass
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2023 | COT - RSBU - Exterior Clips/Sheathing | Partial Pass | 10/24/23:Anchor bolt spacing at exterior perimeter on west side greater than 6' (add anchor bolt where marked, shear wall bottom plate nailing at upstairs south east bedroom missing (6" o.c), king stud at back porch door missing on one side (plans call for 2 king and 2 trimmer on both sides. Shear wall on north west corner anchor bolt spacing greater than 32" o.c. Ok to proceed will check at intermediate. | |
12/22/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |