Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141450690

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0823-01379

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
10/24/2023 COT - RSBU - Exterior Clips/Sheathing  Partial Pass 10/24/23:Anchor bolt spacing at exterior perimeter on west side greater than 6' (add anchor bolt where marked, shear wall bottom plate nailing at upstairs south east bedroom missing (6" o.c), king stud at back porch door missing on one side (plans call for 2 king and 2 trimmer on both sides. Shear wall on north west corner anchor bolt spacing greater than 32" o.c. Ok to proceed will check at intermediate.
12/22/2023 COT - RSBU - Exterior Clips/Sheathing  Passed