Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0823-01373
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Over notched top plate at laundry, plumbing coming outside of sole plate at laundry, sister stud by stairs, sister stud support 4x10 beam at corner of laundry room, add trimmer at back porch entrance at each end, add nails to sole plate at second floor, cut sole plate at bathroom for door, over spanned studs at second floor bathroom. | ||
| 12/13/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |