Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0823-01349
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 11/12/23: Anchor bolt spacing is greater than 6' throughout, anchor bolts missing 12" from edge of bottom plate throughout, anchor bolts at shear wall 11 missing 3"x3" plates, anchor bolt spacing at shear walls is greater then schedule throughout, interior wall shot pins spaced greater than 32" o.c. Roof nailing needs to be re checked. | |
11/16/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |