Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10/20/2026
Concrete fix at front garage entrance for bottom plate. Add anchor bolts at marked locations - Masa clips require 4" spacing from splice edge. SW9 interior garage should touch north wall per plan. SW11 on north wall needs 3"x3" washer plate. Add 12 nails on each side of to- plate splice in rear bathroom as marked. As SW11 requires 3"x3" washer plates. Add sister stud to secure top plate gap at front bedroom. Add nails to loose roof panel in rear as marked. Stopped inspection, more items may apply.
10/22/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10/22/2026
All corrections made.