Inspection Status: Re-inspection required

Inspection History: BULD - Electrical Clearance

Date Description Inspector Results Comments
02/13/2026 BULD - Electrical Clearance Re-inspection required 2/13/26: ELECTRICAL CLEARANCE NOT READY (missing temp receptacle and cover plate at deathfront), missing circuits per approved plans ensure to submit revised plans with correct number of circuits, holiday lighting removed please submit on approved plans, nail plates required throughout, stud shoe required at south exterior bearing wall, properly support flex at 2nd floor, Horizontal ABS drain shall be supported every 4 feet, wiring at powder room exhaust fan shall be properly terminated. Insulation required at hot water lines 3/4"or large, properly support flex duct in closet, pex lines shall be properly supported at powder room,.
02/20/2026 BULD - Electrical Clearance Passed 2.20.26
Approved for ECO
03/20/2026 BULD - Electrical Clearance Passed ECO