Parcel: 141461120


Addresses:

9609 E FRIEDEL DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0725-00390

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10.24.2025
Missing MST60 strap at rear windows per detail SD2-52, add H1 clip to split roof trusses from over-drive long screws as marked.
12/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 12.5.25
Approved