Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/26/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 1-26-26: add shot pins 24" o.c., missing backing/reinforcement at restrooms, Add nails to marked locations at exterior sheathing-north side, add anchor bolts to marked locations, add nails to loose roof panels at marked locations. Make corrections and reschedule an inspection. Note: front & rear framing not done-porches not yet installed. |
|
| 01/27/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 1-27-26: Partial pass pending framing on porches. Also, restroom backing not yet installed but will verify at upcoming framing inspection. Okay to continue with construction at progress areas. | |
| 02/02/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 2-2-26: missing LUS26 hangers, 2 anchor bolts are required at column sill plate ( plate 12" or more in length require 2 a/b's), submit an updated floor plan showing removal of third column at back patio, provide clarification on whether lag screws are required at ledgers for front/rear patios, add CS20 strap at columns (post to beam). | |
| 02/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 2.4.26 Cs20 still required per previous notes Lus28 hangars to be installed per manufacturer specs |