Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141450140


Addresses:

6517 E PASEO ALGA


Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0724-00771

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
01/02/2025 COT - RSBU - Exterior Clips/Sheathing  Passed 1/2/25 corrections made
12/24/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 12/24/24: Anchor bolt spacing at kitchen west wall not per plans, rsp4 missing per plan at porch columns, anchor bolts missing at sill plate at porch columns, shear wall fasteners not per schedule, multiple continuous masa clip with one leg up (only one in three allowed), roof sheathing must be re-walked and properly fastened.