Inspection Status: Passed
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0724-00771
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/02/2025 | COT - RSBU - Exterior Clips/Sheathing | Passed | 1/2/25 corrections made | |
12/24/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 12/24/24: Anchor bolt spacing at kitchen west wall not per plans, rsp4 missing per plan at porch columns, anchor bolts missing at sill plate at porch columns, shear wall fasteners not per schedule, multiple continuous masa clip with one leg up (only one in three allowed), roof sheathing must be re-walked and properly fastened. |