Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 10/05/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
10/5/23: missing anchor bolt on bottom plate 12" from end plate, shearwall 7 calls for anchor bolts spacing at 24" O.C missing one at north and south shear wall. Will check at intermediate. 8"x8" post at entrance calls for clips on both south and west of post (per plan). |
| 10/06/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|