Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 10319001T


Addresses:

2408 W OWL PERCH LP


Inspection Status: Partial Pass

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0723-01278

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
10/05/2023 COT - RSBU - Exterior Clips/Sheathing  Partial Pass 10/5/23: missing anchor bolt on bottom plate 12" from end plate, shearwall 7 calls for anchor bolts spacing at 24" O.C missing one at north and south shear wall. Will check at intermediate. 8"x8" post at entrance calls for clips on both south and west of post (per plan).
10/06/2023 COT - RSBU - Exterior Clips/Sheathing  Passed