Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0723-01278
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Partial Pass
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/05/2023 | COT - RSBU - Exterior Clips/Sheathing | Partial Pass | 10/5/23: missing anchor bolt on bottom plate 12" from end plate, shearwall 7 calls for anchor bolts spacing at 24" O.C missing one at north and south shear wall. Will check at intermediate. 8"x8" post at entrance calls for clips on both south and west of post (per plan). | |
10/06/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |