Permit: TC-MDP-0723-01258

Parcel: 13219068B


Addresses:

4870 S BENTLEY AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
02/22/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 2/22/24: properly insulate wyes at mechanical flex connections, 2-bay garage requires 2 receptacles (1 for each bay), plans call for 12AWG wire at bedroom for receptacles (14AWG installed), properly support flex duct throughout, properly fasten anchor bolts throughout, receptacles throughout call for 12AWG but 14AWG is installed. Copper piping penetrating vapor barrier must be wrapped to avoid corrosion from stucco. kitchen hood duct not properly sealed.
02/26/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
02/29/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed