Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0723-01227
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 8/12/24: anchor bolts needed at shear walls and breake in plates. Sthd 10 outside of garage needs to be nailed in place. Htt5 needs to be set. Window in kitchen missing king studs. Stopped inspection. | ||
08/14/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing h25 at stairway trusses. Secure loose bottom plates that haven't been cut. Loose shear wall at garage area near water heater. 8/14/2024 | |
08/15/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections were made. 8/15/2024 |